A denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds

Typeset version

 

TY  - JOUR
  - Temime, B.,Healy, R. M.,Wenger, J. C.
  - 2007
  - September
  - Environmental Science ; Technology
  - A denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds
  - Validated
  - ()
  - 41
  - 18
  - 6514
  - 20
  - A denuder-filter sampling technique for the simultaneous collection of gas and particle phase carbonyl compounds has been developed and tested. The denuder was coated with XAD-4 resin and the derivatizing agent O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) to enable on-tube conversion of gas-phase carbonyls to their oxime derivatives which were extracted and identified by GC-MS. The performance of the PFBHA-coated denuder was tested on a range of carbonyls, dicarbonyls, aromatic aldehydes, carbonyl-containing furans, and benzoquinones. The collection efficiency of the PFBHA-coated denuder was over 90% for sampling times of 10 min and significantly higher than when using only XAD-4 as the sorbent. The collection efficiency and rate of on-tube derivatization was highest for aldehydes and lowest for ketones, consistent with the expected reactivity of carbonyls with PFBHA. The method was used to separate the gas and particle phase carbonyl products formed during the photooxidation of toluene in order to assess its potential for application to simulation chamber experiments of VOC oxidation. The results indicate that when compared to a conventional filter sampling setup, the PFBHA-coated denuder-filter reduced the extent of gas phase adsorption onto the filter by at least a factor of 2 for each of the carbonyls formed. Further potential applications of the denuder-filter sampling method are discussed.
  - 0013-936X (Print)0013-93
  - http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve;db=PubMed;dopt=Citation;list_uids=17948802
DA  - 2007/09
ER  - 
@article{V16093225,
   = {Temime,  B. and Healy,  R. M. and Wenger,  J. C. },
   = {2007},
   = {September},
   = {Environmental Science ; Technology},
   = {A denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds},
   = {Validated},
   = {()},
   = {41},
   = {18},
  pages = {6514--20},
   = {{A denuder-filter sampling technique for the simultaneous collection of gas and particle phase carbonyl compounds has been developed and tested. The denuder was coated with XAD-4 resin and the derivatizing agent O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) to enable on-tube conversion of gas-phase carbonyls to their oxime derivatives which were extracted and identified by GC-MS. The performance of the PFBHA-coated denuder was tested on a range of carbonyls, dicarbonyls, aromatic aldehydes, carbonyl-containing furans, and benzoquinones. The collection efficiency of the PFBHA-coated denuder was over 90% for sampling times of 10 min and significantly higher than when using only XAD-4 as the sorbent. The collection efficiency and rate of on-tube derivatization was highest for aldehydes and lowest for ketones, consistent with the expected reactivity of carbonyls with PFBHA. The method was used to separate the gas and particle phase carbonyl products formed during the photooxidation of toluene in order to assess its potential for application to simulation chamber experiments of VOC oxidation. The results indicate that when compared to a conventional filter sampling setup, the PFBHA-coated denuder-filter reduced the extent of gas phase adsorption onto the filter by at least a factor of 2 for each of the carbonyls formed. Further potential applications of the denuder-filter sampling method are discussed.}},
  issn = {0013-936X (Print)0013-93},
   = {http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve;db=PubMed;dopt=Citation;list_uids=17948802},
  source = {IRIS}
}
AUTHORSTemime, B.,Healy, R. M.,Wenger, J. C.
YEAR2007
MONTHSeptember
JOURNAL_CODEEnvironmental Science ; Technology
TITLEA denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds
STATUSValidated
TIMES_CITED()
SEARCH_KEYWORD
VOLUME41
ISSUE18
START_PAGE6514
END_PAGE20
ABSTRACTA denuder-filter sampling technique for the simultaneous collection of gas and particle phase carbonyl compounds has been developed and tested. The denuder was coated with XAD-4 resin and the derivatizing agent O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) to enable on-tube conversion of gas-phase carbonyls to their oxime derivatives which were extracted and identified by GC-MS. The performance of the PFBHA-coated denuder was tested on a range of carbonyls, dicarbonyls, aromatic aldehydes, carbonyl-containing furans, and benzoquinones. The collection efficiency of the PFBHA-coated denuder was over 90% for sampling times of 10 min and significantly higher than when using only XAD-4 as the sorbent. The collection efficiency and rate of on-tube derivatization was highest for aldehydes and lowest for ketones, consistent with the expected reactivity of carbonyls with PFBHA. The method was used to separate the gas and particle phase carbonyl products formed during the photooxidation of toluene in order to assess its potential for application to simulation chamber experiments of VOC oxidation. The results indicate that when compared to a conventional filter sampling setup, the PFBHA-coated denuder-filter reduced the extent of gas phase adsorption onto the filter by at least a factor of 2 for each of the carbonyls formed. Further potential applications of the denuder-filter sampling method are discussed.
PUBLISHER_LOCATION
ISBN_ISSN0013-936X (Print)0013-93
EDITION
URLhttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve;db=PubMed;dopt=Citation;list_uids=17948802
DOI_LINK
FUNDING_BODY
GRANT_DETAILS